Iei 212i keypad programming manualIei 212i keypad wiring diagram Iei 212r key pad issuesIei technology 212em keypad installation & programming manual. Iei 212se keypad programming manualIei 212i keypad programming manual : changing code on iei keypad 11 Keypad iei reprogramLinear llc / iei iei-212i fm212 user indooraccess keypad iei. Check Details Iei 212i indoor flush-mount keypad access control linear Iei keypad programming instructionsIei programming series instructions manualzz operating installation gard door Iei keypad indoor outdoor lit surface back qty keys 2000eKeypad iei linear access. Iei 212se keypad programming manualIei 212se keypad programming manual / 1 - Iei 212i keypad programming manual : changing code on iei keypad 11Iei 212se keypad programming manual / 1. International electronics 0-213222 iei weather-resistant keypad system Iei keypad 212r indoor / outdoor surface-mount ruggedized Linear 212i flush mount indoor keypad Iei-212mp iei surface indoor/outdoor keypad with back-lit keys Step 2: Connect the Brown (Normally Open) Relay wire from the 212iL harness to the Normally closed connection on the Door position switch.Iei keypad 212se indoor / outdoor surface-mount weather resistant Iei keypad keypads indoor switches door send friend print andersonlock Keypad 212r gard door iei surface indoor mount outdoor ruggedized linear brands Iei 212I Keypad Programming Manual : Changing Code On Iei Keypad 11 Step 1: Connect the Blue (Common) Relay wire from the 212iL harness to the Common connection on the door position switch. Shunting a Normally Closed Zone: (see below) Step 3: Splice together the Black Negative voltage wire on the 212iL harness (negative voltage coming from the power supply) to the Negative connection on the Electric door strike. Step 2: Connect the Brown (Normally Open) wire from the 212iL harness to the Positive voltage connection on the Electric door strike. (Until you supply the common leg of the relay with voltage). This means that there is no voltage running through the relay. The 212iL is equipped with a Form C, Dry contact relay on board. If you are sharing the same DC voltage power supply with the 212iL and the Electric Strike, (that is to say if you have only one power supply for both the 212iL and the lock device), you need to run voltage through the common (Blue) wire on the 6 conductor wire harness of the 212iL. Wiring to an Electric Strike: (see below) Step 3: Splice together the Black Negative voltage wire on the 212iL harness (negative voltage coming from the power supply) to the Negative connection on the Magnetic lock. Step 2: Connect the White /Yellow wire (Normally Closed) from the 212iL harness to the Positive connection on the Magnetic lock. (Positive voltage coming from the power supply.)
![iei 212i flush mount indoor keypad manual iei 212i flush mount indoor keypad manual](https://www.gokeyless.com/wp-content/uploads/2015/03/267-250x250.jpg)
Step 1: Splice together the Blue Relay Common wire from the 212iL harness to the Red wire on the 212iL harness. The reason is that the 212iL is equipped with a Form C, Dry contact relay on board.
![iei 212i flush mount indoor keypad manual iei 212i flush mount indoor keypad manual](https://m.media-amazon.com/images/I/51B3IozHCyL._AC_SY355_.jpg)
If you are sharing the same DC voltage power supply with the 212iL and the magnetic lock, (that is to say if you have only one power supply for both the 212iL and the lock device), you need to run voltage through the common (Blue) wire on the 6 conductor wire harness of the 212iL. Next you will need to attach the relay wires (white/yellow, blue, and brown) to the wire run that is connected to the locking device. Attach the 6-conductor wire harness to the plug in connector on the back of the 212iL.Ģ. Temperature Tolerance: Standard, -20 ° to 130☏.ġ. Maximum Current Draw allowed voltages: 140mA. Operating Voltages: 12-24 VDC only on input voltage. The 212iL should be mounted to a standard single gang electrical box (with the small slot in the trim ring facing down), but it also is able to mount directly to a flat indoor surface with the provided mounting screws. Be sure that the 212iL is mounted indoors ONLY!
![iei 212i flush mount indoor keypad manual iei 212i flush mount indoor keypad manual](https://cdn11.bigcommerce.com/s-1lji4r5cj2/images/stencil/1280x1280/products/5148/39766/IEI-212I-Indoor-Flush-Mount-Keypad__S_3__37124.1655757479.jpg)
Mounting height is the same for an electrical switch, 48" on center. Select the appropriate location for the 212iL. Taking this inventory will familiarize you with the components as well as ensure that you have a complete parts list. Please check the contents of this package and verify all components in the packing list are present. Q Section 1: Unpacking and checking the packing listĢ 1 1/4" black, socket cap flat head machine screwsĢ 1 1/4" black, Phillips flat head sheet metal screws V Programmable 00-99 Second Relay Activation Time Single Unit KeypadControl Installation Manual